Availability: | |
---|---|
ZLS
CTBU
Introduction:
Model ZLS Two stage FR3 Dielectric oil filtering machine can efficiently remove free water, dissolved water, gas, particles as well as acetylene, hydrogen, methane and other harmful ingredients from oil effectively to improve oil's dielectric strength level, effectively to make sure electric equipment working safely and normally.
It applies to 110KV, 132KV, 220KV, 500KV oil transformers.
Brand CTBU Two stage vacuum FR3 Dielectric oil filter system is specially suitable for treating HV transformer oil, super-voltage transformer oil. It can be used for filtration of more than 110KV substation work onsite. Meanwhile, it also can process switch oil, mutual inductor oil, cable oil, circuit breaker oil, capacitor oil and other insulating oil series.
Series ZLS Vacuum FR3 oil filtration can be used as independent vacuum source with functions of vacuum drying and vacuum filling for transformers and electric equipment.
(Options:CTBU brand ZLS FR6 oil Filter machine also can equips used transformer oil regeneration plant, it can regenerate the unqualified old/used transformer oil, remove acidity, free carbon, sludge, oxides, pigment, other soluble oil products and discolor)
Optional: Online moisture monitor, flow meter, oil regeneration system, weather proof canopy, double axles or single axle trailer, dielectric strength tester, etc.
Technical Specifications:
Model | ZLS-30 | ZLS-50 | ZLS-75 | ZLS-100 | ZLS-150 | ZLS-200 | ZLS-250 | ZLS-300 | |
Flow (liters/hour) | 1800 | 3000 | 4500 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Vacuum degree | -0.08~-0.099 Mpa | ||||||||
Working pressure | ≤ 0.4 Mpa | ||||||||
Ultimate vacuum | ≤ 5 Pa | ||||||||
Temperature range | 20-80℃ | ||||||||
Breakdown voltage | ≥ 70KV | ||||||||
Water content | ≤ 5ppm | ||||||||
Gas content | ≤ 0.1% | ||||||||
Filtering rate | ≥ 99.5% | ||||||||
Particle size | ≤3micron | ||||||||
Power supply | 220V/380V/400V/415V/440V/460V/480V/575V(±10%), 50/60Hz, 3Phase | ||||||||
Working noise | 65 dB | ||||||||
Heating power (kw) | 30 | 36 | 60 | 72 | 120 | 150 | 180 | 215 | |
Total power (kw) | 35 | 42 | 66 | 80 | 133 | 165 | 195 | 230 | |
Inlet/outlet(mm) | 32 | 32 | 44 | 44 | 50 | 55 | 60 | 65 | |
Weight (kg) | 600 | 700 | 800 | 900 | 1100 | 1300 | 1550 | 1800 | |
Dimension (mm) | L | 1600 | 1600 | 1700 | 1850 | 1900 | 2000 | 2100 | 2200 |
W | 1500 | 1550 | 1650 | 1750 | 1800 | 1850 | 1900 | 2000 | |
H | 1600 | 1600 | 1700 | 1800 | 1850 | 1850 | 1900 | 2000 |
If you have special requirement, please contact CTBU. CTBU have different designs as per different requirements:
• Vertical shape.
• "T" shape.
• Horizontal shape.
Introduction:
Model ZLS Two stage FR3 Dielectric oil filtering machine can efficiently remove free water, dissolved water, gas, particles as well as acetylene, hydrogen, methane and other harmful ingredients from oil effectively to improve oil's dielectric strength level, effectively to make sure electric equipment working safely and normally.
It applies to 110KV, 132KV, 220KV, 500KV oil transformers.
Brand CTBU Two stage vacuum FR3 Dielectric oil filter system is specially suitable for treating HV transformer oil, super-voltage transformer oil. It can be used for filtration of more than 110KV substation work onsite. Meanwhile, it also can process switch oil, mutual inductor oil, cable oil, circuit breaker oil, capacitor oil and other insulating oil series.
Series ZLS Vacuum FR3 oil filtration can be used as independent vacuum source with functions of vacuum drying and vacuum filling for transformers and electric equipment.
(Options:CTBU brand ZLS FR6 oil Filter machine also can equips used transformer oil regeneration plant, it can regenerate the unqualified old/used transformer oil, remove acidity, free carbon, sludge, oxides, pigment, other soluble oil products and discolor)
Optional: Online moisture monitor, flow meter, oil regeneration system, weather proof canopy, double axles or single axle trailer, dielectric strength tester, etc.
Technical Specifications:
Model | ZLS-30 | ZLS-50 | ZLS-75 | ZLS-100 | ZLS-150 | ZLS-200 | ZLS-250 | ZLS-300 | |
Flow (liters/hour) | 1800 | 3000 | 4500 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Vacuum degree | -0.08~-0.099 Mpa | ||||||||
Working pressure | ≤ 0.4 Mpa | ||||||||
Ultimate vacuum | ≤ 5 Pa | ||||||||
Temperature range | 20-80℃ | ||||||||
Breakdown voltage | ≥ 70KV | ||||||||
Water content | ≤ 5ppm | ||||||||
Gas content | ≤ 0.1% | ||||||||
Filtering rate | ≥ 99.5% | ||||||||
Particle size | ≤3micron | ||||||||
Power supply | 220V/380V/400V/415V/440V/460V/480V/575V(±10%), 50/60Hz, 3Phase | ||||||||
Working noise | 65 dB | ||||||||
Heating power (kw) | 30 | 36 | 60 | 72 | 120 | 150 | 180 | 215 | |
Total power (kw) | 35 | 42 | 66 | 80 | 133 | 165 | 195 | 230 | |
Inlet/outlet(mm) | 32 | 32 | 44 | 44 | 50 | 55 | 60 | 65 | |
Weight (kg) | 600 | 700 | 800 | 900 | 1100 | 1300 | 1550 | 1800 | |
Dimension (mm) | L | 1600 | 1600 | 1700 | 1850 | 1900 | 2000 | 2100 | 2200 |
W | 1500 | 1550 | 1650 | 1750 | 1800 | 1850 | 1900 | 2000 | |
H | 1600 | 1600 | 1700 | 1800 | 1850 | 1850 | 1900 | 2000 |
If you have special requirement, please contact CTBU. CTBU have different designs as per different requirements:
• Vertical shape.
• "T" shape.
• Horizontal shape.