Availability: | |
---|---|
ZLS-T
CTBU
Working areas:
In High voltage substations.
Subject to the field of 30KV voltage, 90kV,132KV, 400 kV and 220kV, 500KV, etc.
Protection against the weather by a metallic Housing doors.
The control panel, cabling and protective devices are withstand transport constraints and word owner operating vibration equipping the machine.
What can the CTBU machine do for you?
The two stage trailer mounted transformer oil purification machine is required to provide the following functions:
A nominal rate of at least 6000Liter or adjustable.
Purification of oil transformers out of service.
Oil Filtration: removal of solid particles suspended in the oil.
Vacuum Dehydration: extraction of water dissolved in the oil.
Gas Venting: extraction of gas are dissolved in oil.
Reference standard:
The purpose of the transformer oil purifying operation is to bring the mineral insulating oils into conformity with the standards listed below (including the test procedures):
IEC 60296: Fluids for electrotechnical applications
IEC 60422: Mineral insulating oils in electrical equipment - Lines. Guidelines for maintenance and monitoring
IEC 60156: Determination of breakdown voltage at industrial frequency,
NFC 15100: Low-voltage electrical installations,
ISO 4406: Hydraulic fluid power - Fluids - Method for coding the level of contamination by solid particles
Features:
The transformer oil filtration machine can be able for use with none energized power transformer and will have:
1. Oil flow rate 5000 liter/hour or more.
2. The heating speed can be more than one step.
3. Vacuum level can be between one to four absolute m bars.
4. The minimum filtration range can be not less than 2 absolute μ.
5. Dissolved moisture on the final content can be <7ppm.
6. The dissolved gas on the final content can be <0.2% by volume.
7. Can reach with the treat oil a dielectric strength not less than 70kv.
Technical Specifications:
Item | Parameter | Unit | Model ZLS | ||||||
Technical Data | Flow Rate | L/H | 3000 | 4000 | 6000 | 9000 | 12000 | 18000 | |
Working Vacuity | Pa | ≤133 | |||||||
Pressure | Mpa | ≤0.35 | |||||||
Temperature Range | ℃ | 45-65 | |||||||
Power Supply | as customer required | ||||||||
Total Power | KW | 48 | 78 | 90 | 120 | 150 | 230 | ||
Inlet/Outlet Diameter | mm | 25 | 32 | 38 | 40 | 50 | 65 | ||
Size | Length | mm | 1600 | 1800 | 2200 | 2500 | 2800 | 3450 | |
Width | mm | 1250 | 1450 | 1600 | 1950 | 2150 | 2600 | ||
Height | mm | 2000 | 2200 | 2450 | 2700 | 3000 | 3000 | ||
Weight | Kg | 500 | 700 | 1460 | 1800 | 2400 | 4000 | ||
Performance | Dielectric Strength | KV | ≥75KV(spherical electrodes) | ||||||
Water Removal | ppm | ≤5 | |||||||
Gas Removal | % | ≤0.1 | |||||||
Particles Removal | µm | 3micron |
If you have special requirement, please contact CTBU. CTBU have different designs as per different requirements:
• Vertical shape.
• "T" shape.
• Horizontal shape.
Working areas:
In High voltage substations.
Subject to the field of 30KV voltage, 90kV,132KV, 400 kV and 220kV, 500KV, etc.
Protection against the weather by a metallic Housing doors.
The control panel, cabling and protective devices are withstand transport constraints and word owner operating vibration equipping the machine.
What can the CTBU machine do for you?
The two stage trailer mounted transformer oil purification machine is required to provide the following functions:
A nominal rate of at least 6000Liter or adjustable.
Purification of oil transformers out of service.
Oil Filtration: removal of solid particles suspended in the oil.
Vacuum Dehydration: extraction of water dissolved in the oil.
Gas Venting: extraction of gas are dissolved in oil.
Reference standard:
The purpose of the transformer oil purifying operation is to bring the mineral insulating oils into conformity with the standards listed below (including the test procedures):
IEC 60296: Fluids for electrotechnical applications
IEC 60422: Mineral insulating oils in electrical equipment - Lines. Guidelines for maintenance and monitoring
IEC 60156: Determination of breakdown voltage at industrial frequency,
NFC 15100: Low-voltage electrical installations,
ISO 4406: Hydraulic fluid power - Fluids - Method for coding the level of contamination by solid particles
Features:
The transformer oil filtration machine can be able for use with none energized power transformer and will have:
1. Oil flow rate 5000 liter/hour or more.
2. The heating speed can be more than one step.
3. Vacuum level can be between one to four absolute m bars.
4. The minimum filtration range can be not less than 2 absolute μ.
5. Dissolved moisture on the final content can be <7ppm.
6. The dissolved gas on the final content can be <0.2% by volume.
7. Can reach with the treat oil a dielectric strength not less than 70kv.
Technical Specifications:
Item | Parameter | Unit | Model ZLS | ||||||
Technical Data | Flow Rate | L/H | 3000 | 4000 | 6000 | 9000 | 12000 | 18000 | |
Working Vacuity | Pa | ≤133 | |||||||
Pressure | Mpa | ≤0.35 | |||||||
Temperature Range | ℃ | 45-65 | |||||||
Power Supply | as customer required | ||||||||
Total Power | KW | 48 | 78 | 90 | 120 | 150 | 230 | ||
Inlet/Outlet Diameter | mm | 25 | 32 | 38 | 40 | 50 | 65 | ||
Size | Length | mm | 1600 | 1800 | 2200 | 2500 | 2800 | 3450 | |
Width | mm | 1250 | 1450 | 1600 | 1950 | 2150 | 2600 | ||
Height | mm | 2000 | 2200 | 2450 | 2700 | 3000 | 3000 | ||
Weight | Kg | 500 | 700 | 1460 | 1800 | 2400 | 4000 | ||
Performance | Dielectric Strength | KV | ≥75KV(spherical electrodes) | ||||||
Water Removal | ppm | ≤5 | |||||||
Gas Removal | % | ≤0.1 | |||||||
Particles Removal | µm | 3micron |
If you have special requirement, please contact CTBU. CTBU have different designs as per different requirements:
• Vertical shape.
• "T" shape.
• Horizontal shape.