Availability: | |
---|---|
ZLS
CTBU
Introduction:
Model ZLS Two stage transformer oil purification plant can efficiently remove free water, dissolved water, gas, particles as well as acetylene, hydrogen, methane and other harmful ingredients from oil effectively to improve oil's dielectric strength level.
The Two stage vacuum transformer oil purification system is specially suitable for treating HV transformer oil, super-voltage transformer oil. It can be used for filtration of more than 110KV substation work onsite. Meanwhile, it also can process switch oil, mutual inductor oil, cable oil, circuit breaker oil, capacitor oil and other insulating oil series.
CTBU brand Vacuum transformer oil dryer can be used as independent vacuum source with functions of vacuum drying and vacuum filling for transformers and electric equipment.
(Options:CTBU brand ZLS vacuum dry machine also can equips used dielectric oil regeneration plant, it can regenerate the unqualified old/used transformer oil, remove acidity, free carbon, sludge, oxides, pigment, other soluble oil products and discolor)
Optional: Online moisture monitor, flow meter, oil regeneration system, weather proof canopy, double axles or single axle trailer, dielectric strength tester, etc.
Technical Specifications:
Model | ZLS-30 | ZLS-50 | ZLS-75 | ZLS-100 | ZLS-150 | ZLS-200 | ZLS-250 | ZLS-300 | |
Flow (liters/hour) | 1800 | 3000 | 4500 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Vacuum degree | -0.08~-0.099 Mpa | ||||||||
Working pressure | ≤ 0.4 Mpa | ||||||||
Ultimate vacuum | ≤ 5 Pa | ||||||||
Temperature range | 20-80℃ | ||||||||
Breakdown voltage | ≥ 70KV | ||||||||
Water content | ≤ 5ppm | ||||||||
Gas content | ≤ 0.1% | ||||||||
Filtration | ≥ 99.5% | ||||||||
Filtering precision | ≤3micron | ||||||||
Power supply | 220V/380V/400V/415V/440V/460V/480V/575V(±10%), 50/60Hz, 3Phase | ||||||||
Working noise | 65 dB | ||||||||
Heating power (kw) | 30 | 36 | 60 | 72 | 120 | 150 | 180 | 215 | |
Total power (kw) | 35 | 42 | 66 | 80 | 133 | 165 | 195 | 230 | |
Inlet outlet(mm) | 32 | 32 | 44 | 44 | 50 | 55 | 60 | 65 | |
Weight (kg) | 600 | 700 | 800 | 900 | 1100 | 1300 | 1550 | 1800 | |
Dimension (mm) | L | 1600 | 1600 | 1700 | 1850 | 1900 | 2000 | 2100 | 2200 |
W | 1500 | 1550 | 1650 | 1750 | 1800 | 1850 | 1900 | 2000 | |
H | 1600 | 1600 | 1700 | 1800 | 1850 | 1850 | 1900 | 2000 |
If you have special requirement, please contact CTBU. CTBU have different designs as per different requirements:
• Vertical shape.
• "T" shape.
• Horizontal shape.
Introduction:
Model ZLS Two stage transformer oil purification plant can efficiently remove free water, dissolved water, gas, particles as well as acetylene, hydrogen, methane and other harmful ingredients from oil effectively to improve oil's dielectric strength level.
The Two stage vacuum transformer oil purification system is specially suitable for treating HV transformer oil, super-voltage transformer oil. It can be used for filtration of more than 110KV substation work onsite. Meanwhile, it also can process switch oil, mutual inductor oil, cable oil, circuit breaker oil, capacitor oil and other insulating oil series.
CTBU brand Vacuum transformer oil dryer can be used as independent vacuum source with functions of vacuum drying and vacuum filling for transformers and electric equipment.
(Options:CTBU brand ZLS vacuum dry machine also can equips used dielectric oil regeneration plant, it can regenerate the unqualified old/used transformer oil, remove acidity, free carbon, sludge, oxides, pigment, other soluble oil products and discolor)
Optional: Online moisture monitor, flow meter, oil regeneration system, weather proof canopy, double axles or single axle trailer, dielectric strength tester, etc.
Technical Specifications:
Model | ZLS-30 | ZLS-50 | ZLS-75 | ZLS-100 | ZLS-150 | ZLS-200 | ZLS-250 | ZLS-300 | |
Flow (liters/hour) | 1800 | 3000 | 4500 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Vacuum degree | -0.08~-0.099 Mpa | ||||||||
Working pressure | ≤ 0.4 Mpa | ||||||||
Ultimate vacuum | ≤ 5 Pa | ||||||||
Temperature range | 20-80℃ | ||||||||
Breakdown voltage | ≥ 70KV | ||||||||
Water content | ≤ 5ppm | ||||||||
Gas content | ≤ 0.1% | ||||||||
Filtration | ≥ 99.5% | ||||||||
Filtering precision | ≤3micron | ||||||||
Power supply | 220V/380V/400V/415V/440V/460V/480V/575V(±10%), 50/60Hz, 3Phase | ||||||||
Working noise | 65 dB | ||||||||
Heating power (kw) | 30 | 36 | 60 | 72 | 120 | 150 | 180 | 215 | |
Total power (kw) | 35 | 42 | 66 | 80 | 133 | 165 | 195 | 230 | |
Inlet outlet(mm) | 32 | 32 | 44 | 44 | 50 | 55 | 60 | 65 | |
Weight (kg) | 600 | 700 | 800 | 900 | 1100 | 1300 | 1550 | 1800 | |
Dimension (mm) | L | 1600 | 1600 | 1700 | 1850 | 1900 | 2000 | 2100 | 2200 |
W | 1500 | 1550 | 1650 | 1750 | 1800 | 1850 | 1900 | 2000 | |
H | 1600 | 1600 | 1700 | 1800 | 1850 | 1850 | 1900 | 2000 |
If you have special requirement, please contact CTBU. CTBU have different designs as per different requirements:
• Vertical shape.
• "T" shape.
• Horizontal shape.