1. General
Mobile units of oil treatment plant for power transformer with fully metal enclosure for working at the site in the wild environment, it can vacuum the transformer during the transformer's installation and maintenance at site, and ZLS can also do the job of the vacuum dehydrating and vacuum degassing of transformer oil, and to shorten the oil treating time.
CTBU oil treatment plant is being capable to re-improve the power transformer oil characteristics up to the recommended value by the transformer manufacturer or IEC60296 and other IEC standard
The oil treatment unit is designed to carry out the operations of filtration, dehydration and absorption of dissolved gases in a transformer for non- energized transformers either for their filling up with oil or for their Periodic maintenance.
The Oil Treatment Plant can be PLC fully automatic or manual operation.
2. Technical parameters
Model | ZLS-30 | ZLS-50 | ZLS-70 | ZLS-100 | ZLS-150 | ZLS-200 | ZLS-250 | ZLS-300 |
Flow (liter/hour) | 1800 | 3000 | 4000 | 6000 | 9000 | 12000 | 15000 | 18000 |
Vacuum degree | -0.08~-0.099 Mpa |
Working pressure | ≤ 0.4 Mpa |
Temperature range | 20-80℃ |
Breakdown voltage | ≥ 70KV |
Water content | ≤ 5ppm |
Gas content | ≤ 0.1% |
Cleaning rate | ≥ 99.5% |
Filtering precision | ≤3micron |
Power supply | 220V/380V/400V/415V/440V/460V/480V/575V(±10%), 50/60Hz, 3Phase |
Working noise | 65 dB |
Heating power (kw) | 30 | 36 | 60 | 72 | 96 | 120 | 160 | 200 |
Total power (kw) | 35 | 42 | 66 | 80 | 105 | 130 | 170 | 220 |
Inlet outlet(mm) | 25 | 32 | 38 | 40 | 50 | 55 | 60 | 65 |
Weight (kg) | 600 | 700 | 800 | 900 | 1100 | 1300 | 1550 | 1800 |
Dimension (mm) | L | 1600 | 1600 | 1700 | 1850 | 1900 | 2000 | 2100 | 2200 |
W | 1500 | 1550 | 1650 | 1750 | 1800 | 1850 | 1900 | 2000 |
H | 1600 | 1600 | 1700 | 1800 | 1850 | 1850 | 1900 | 2000 |